DxH 900 Workcell Automated Hematology Solution

Workcell Configuration Detail Maximum Throughput Width Depth Height Weight**
DxH SMS II 1 DxH SMS 140 Smears/Hour 94 cm (37 in) 78.74 cm (31 in) SMS; 204.5 cm (80.5 in) 353.84 kg (780 lbs)
DxH 900 1 DxH 900 100 Samples/Hour 75.57 cm (29.75 in) 82.80 cm (32.6 in) including the removable back panel 79.25 cm (31.2 in) excluding the removable back panel DxH 900 174 cm (68.5 in) 194 cm (76.4 in) with cover lifted 254 kg (560 lbs)
DxH 900-S 1 DxH 900 with SMS 100 Samples/Hour 170.53 cm (67.13 in) 82.80 cm (32.6 in) including the removable back panel 79.25 cm (31.2 in) excluding the removable back panel DxH 900 174 cm (68.5 in) 194 cm (76.4 in) with cover lifted 608 kg (1340 lbs)
DxH 900-2 2 DxH 900 200 Samples/Hour 152.1 cm (59.88 in) 82.80 cm (32.6 in) including the removable back panel 79.25 cm (31.2 in) excluding the removable back panel DxH 900 174 cm (68.5 in) 194 cm (76.4 in) with cover lifted 508 kg (1120 lbs) excluding reagents 680 kg (1500 lbs) including reagents
DxH 900-3 3 DxH 900 300 Samples/Hour 228.63 cm (90.01 in) 82.80 cm (32.6 in) including the removable back panel 79.25 cm (31.2 in) excluding the removable back panel DxH 900 174 cm (68.5 in) 194 cm (76.4 in) with cover lifted 762 kg (1680 lbs)
DxH 900-3S 3 DxH 900 with SMS 300 Samples/Hour 323.59 cm (127.39 in) 82.80 cm (32.6 in) including the removable back panel 79.25 cm (31.2 in) excluding the removable back panel DxH 900 174 cm (68.5 in) 194 cm (76.4 in) with cover lifted 1116 kg (2460 lbs)
Additional clearance; 3.8 cm (1.5 in) behind instrument for sufficient cooling, 15.2 cm (6.0 in) per side.  
Whole Blood Reportable Range Precision
WBC x103 cells/μL 0.050–400.000 <3.0% -5% CV
RBC x106 cells/μL 0.005–8.500 <1.5% CV
HGB g/dL 0.10–25.50 <1.5% CV
MCV fL 50.00–150.00 <1.0% CV
PLT x103 cells/μL 3.0–3000.00 <3.5% CV
MPV fL 5.00–25.00 <2.5% CV @PLT >100x103 cells/μL
 
Body Fluid Reportable Range Precision
TNC cells/mm3 20–89,000 <10.0% CV
RBC cells/mm3 1,000–6,200,000 <15.0% CV
 

Sample Aspiration

Whole Blood and Body Fluid; 165 μL aspiration volume; 0.5 ml dead volume,
Pre-dilute with X5 dilution mode; 50 μL whole blood into 200 μL of Diluent,
SMS; 90 μL for up to 4 smears

Methodology

Enhanced Coulter Digital Impedance, 360 VCS with DataFusion

Available Test Menu

CBC: WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW, RDW-SD, PLT, MPV
Differential: NE, LY, MO, EO, BA, MDW, NRBC, NE#, LY#, MO#, EO#, BA#, NRBC#
Monocyte Distribution Width (MDW) (when enabled)
Retic: RET, RET#, MRV, IRF
Body fluids (CSF, Serous and Synovial): TNC, RBC, @BFM%, @BFP%

Reagents (CBC/Diff/Retic)* and Controls

Coulter DxH Diluent................628017 10 L
Coulter DxH Cell Lyse............628019 5 L
Coulter DxH Diff Pack............628020 EA
Coulter DxH Retic Pack.........628021 EA
6C Plus Cell Control 12x3.5 mL...........................PN C07297
6C Cell Control 9x3.5 mL......................................PN A59925
6C Cell Control 12x3.5 mL.....................................PN 628027
Latron Control 8x4 mL, CP-X..............................PN 628024
S-CAL Calibrator 1x3.3 mL....................................PN 628026
Reticulocyte Controls Retic-X (12x3.5 mL)...PN 628028
Body Fluid Control 12x3.5 mL.............................PN 628030
Linearity Product Lin-X..........................................PN 628029

Cleaner

Coulter DxH Cleaner 628023 10 L—Preloaded for autonomous Daily Cleaning

Power Consumption

Dual indentical power computers in a workcell. DxH 900 SPM; 520 W (1775 BTU/Hour), Monitor: 35W (120 BTU/Hour), DxH Server Computer: 160 W (546 BTU/Hour), DxH Slidemaker Stainer II SPM, 550 W (1877 BTU/Hour)

Data Management

Up to 100,000 patient results with histograms, scatterplots and demographics

Quality Assurance

QC with Levy-Jennings graph; XB/XM for moving averages, daily check, intelligent quality monitoring, customizable calibration and QC reminders and alerts, auto export of QC

Sample Transport

Capacity: 20 five-tube cassettes per module (up to maximum of 400 samples with a DxH 900-3S). Barcodes: digital barcode with 2D barcode capability, Sample ID: up to 22 characters

Remote Monitoring

PROService remote management system: maximum uptime with walk-away troubleshooting and preemptive alerts of instrument issues with RAP box

Power Supply Specifications

A three-wire AC outlet, single phase power supplying 90-264 Vac at 48 to 63 Hz

Acoustic Noise Level

60 dBa

Radio Frequency and Interference Immunity

Meets by the product level standards EN 61326-1 (Electrical Equipment for Measurement, Control, and Laboratory Use - EMC Requirements), and EN 61326-2-6
*Cyanide free reagents
**Excluding reagents

DxH Concentrated Eco Diluent Specifications

RPI-ECO21 Instrument

Instrument size

L 30.5 in (775 mm) x W 24.4 in (620 mm) x H 29.5 in (750 mm)

Empty weight

236 lbs. (107 Kg) including Millipore WPU AFS-24

Dilution method

Electrical Conductivity and Temperature measurement (EC-T)

Conductivity production range

Upon request (indication 10 -20 mS/cm @25°C)

Production capacity

~20 L/hr. peak (for 3 hours)
<17 L/hr. continuous (excluding lot-change and service)

Number of DxH concentrated ECO Diluent

2 x 10L, hot swappable for continuous 360L of diluted diluent

Display specifications

154 x 90 mm (7 in), 1024 x 600 resolution

Storage medium

Onboard memory & data export storage (USB)

Stored data

Batch production and reagent traceability information

Data on Cubitainer NFC tag

Reagent type, dilution target, origin, production date, lot number, ID, shelf life, remaining volume
Eco-friendly DxH ECO Reagents to be used (cyanide-free and low formaldehyde ≤2 ppm)

Cubitainer positions and orientation

2, upright for use in the diluter

Cubitainer volume

10L

Concentration ratio

18x

Storage temperature

Displayed in GUI and monitored (not controlled)

Intra lot cubitainer switching

Uninterrupted production
Electrical requirements

Mains voltage

115 or 230V (± 10%), 50-60 Hz (± 3%)

Fuse EU

2x 3.15A T (Slow blow)

Fuse USA

2x 6A T (Slow blow)

Power consumption

500 VA
Built in Water Production Unit

Water Purification Unit (WPU)

Merck Millipore AFS-24

Feed water temperature

10 - 30°C

Input water connection

1x John Guest PM Acetal fitting 8 mm

Produced water quality

Clinical laboratory reagent water, conductivity ≥ 1MΩ/cm
Input Water Parameters

Pressure

1 to 6 bars

Flow rate

> 5 L/min at 2 bars

Type

Potable tap water

Temperature

10 – 30°C

Conductivity

100 – 2000 μS/cm @ 25°C

pH

4-10

Langelier Saturation Index (LSI)

< 0.3

Free total chlorine

< 3 ppm
Concentrated Diluent Pack Control Process

Control method

QC cycle using RPI-Check

Frequency

≥1x per 24 hr. in manual start and time scheduled

DxH 900 Workcell Automated Hematology Solution